부여템프콘, 부여 중고사출기, 부여설비 BooyeoTempcon

Skip to Container

Steam Temperature ControllerPatent Application No. 10-0621511

The control of the high mold temperature is
playing the key roles from the improvement of the products.

The steam temperature controller can suddenly rise the mold temperature by supplying the high temperature steam, and can make the resin flow smooth. Also, it can shorten the cycle time of the product by supplying the cooling water in time. In this result, the steam temperature controller is suitable for the precise products.

Feature

  • Instantaneous temperature of the steam supply to minimize the initial manufacturing defects (Max. Steam temperature 180℃)
  • Resolve problems such as weld line, black spots and gas emissions etc. by supplying high temperature of steam
  • Smooth flow of water to remove the weld lines 100%
  • Increase productivity by reducing cooling time and supplying cooling water with high pressure quickly

Flow Chart

Body Structure

  1. Monitor (Touch screen)
  2. Left, mold temperature sensor connector - fixed
    Right, mold temperature sensor connector - movable
  3. Control connector linking device
  4. Main power cable connection part
  5. Mold input - 40A (1 1/2")
  6. Steam input - 40A (1 1/2")
  7. Cooling water input - 40A (1 1/2")a
  8. Mold output - 40A (1 1/2")
  9. Main(cooling water) output - 40A (1 1/2")
  10. Air input (15A 1 1/2")

Weldless - New Molding Method

  • Weld-line 100% Remove
  • Steam molding method can rise and lovwer the mold temperature in a short time, it can realize the non-coating by weldless
  • Improvement the productivity by shortening 1 cycle time.
  • Securing the high quality of the exterior parts

Before and After

Specification

Product type ITC-4050
Input Heating start-up signal Emergency stop signal for Mold temperature sensor Mold temperature
Sensor (K-type temperature sensor) Fixed and Movable part (each 1ea)
Output Temperature upper-limit signal
(No contact point)
a contact point
Temperature lower-limit signal
(No contact point)
a contact point
Connecting Pipe Cooling water input part 40A (1 1/2")
Output part 40A (1 1/2")
Steam input part 40A (1 1/2")
Mold input part 40A (1 1/2")
Mold output part 40A (1 1/2")
Air input part 15A (1/2")
Input mediate material Cooling water
  • water capacity (130~200 L/min), water pressure (0.15~0.3Mpa)
  • For the cooling water, use the clear water with many minerals not to accumulate the scale.
Steam input from the steam boiler
Air Air capacity (1 CYCLE / 1,060 CC) / air pressure (0.49~0.8 Mpa)
Out mediate material Use the fixed pipe line to output the hot water with high temperature and pressure.
Or, use the output pipe without pressure.
Pump Power Supply 220V/380/440 3 circuits/4 circuits 50/60Hz (Option)
Type Centrifugal type
Capacity 2.3 kw
Power
connection
220V/380/440 3 circuits 150/60Hz
Main-cable 3.5mm
Grounding D-type grounding

Information